Back to Wall Bath 1700mm: Sizes, Fit and Installation
by Shivam Tayal 26 Nov 2026 0 Comments
You've measured wall to wall three times and got the same number every time. The bath on the screen says 1700 mm, so it should slot straight in. Then the sheeting goes up, the waterproofing goes on, the tiles go on, and the gap you measured isn't the gap you've got. The finished cavity, not the number on the product page, is the true fit test for a back to wall bath 1700mm.
There's a second test hiding behind the wall. A back to wall bath conceals its waste, its overflow and sometimes its tapware behind the bath body, and once the bath is set and sealed, none of it is reachable without breaking tiles.
Both questions get answered on paper before anything is delivered. Check the finished recess, check the waste route, then order.
1700mm Back to Wall Bath Dimensions and Floor Space
| Measure | Value | What it means |
|---|---|---|
| Nominal external length | 1700 mm | Upper end of standard Australian bath lengths |
| Typical width | 700-800 mm | Common range for back to wall models |
| Floor footprint at 750 mm width | About 1.275 m² | Before circulation space is added |
| Finished recess width | At least 1700 mm plus fitting tolerance | Tile, adhesive and waterproofing reduce the rough frame |
| Finished rim height | Model specific, taken from the selected bath | Confirm it on site before tiling and waterproofing |
A 1700 mm back to wall bath sits at the upper end of the standard Australian bath-length range, alongside 1500 mm and 1600 mm models, with widths that commonly run from 700 mm to 800 mm, per independent bathroom-dimension guidance from Joyce Kitchens. The format is predictable, but the fit depends on more than the listed length. In a conventional wall-to-wall recess, 1700 mm often replaces an existing built-in bath because the rear edge stays fixed against the wall and the service zone remains close to that wall.
The same consumer guidance shows how the alternative behaves, which is why 1700 mm survives in rooms where a freestanding bath would take more space.

The footprint is where the arithmetic starts. A bath nominally 750 mm wide takes about 1.275 m² of floor area before you allow for circulation around it, and that is the figure to carry into planning. Freestanding baths generally need open space around the body for cleaning and access, while a back to wall bath removes one entire long edge from the calculation. That matters in a small bathroom, where the saved edge can be the difference between a workable path and a tight one.
Why the listed length isn't the space the bath needs
The number on the product page is the nominal external length. The finished recess has to accept the bath after the wall has been built up. Tile thickness, adhesive bed, waterproofing build-up, skirting or trim, and any movement joint at each end all reduce the clear opening. Take the room's finished dimensions, not the frame's, and check the tapware position and the route you will carry the bath in through at the same time.
Rim height belongs on the same list. It is set by the selected model, fixed before tiling and waterproofing, and it decides where tile coursing lands around the bath. Choosing a bath before you know that height leaves the set-out chasing a number you did not check. I would treat the rim height and the finished recess as one decision, because either one can force a change to the other.
Before you spend anything, mark it out on the floor. Run tape at 1700 mm and at the bath's width, walk the outline with the door closed and then open, sit on the edge where the toilet will be, and see whether you can still get past the vanity. If the tape outline already feels tight, the finished cavity will be tighter.
Back to Wall Versus Other Bath Types
| Bath type | Floor footprint | Cleaning access | Install complexity | Best fit |
|---|---|---|---|---|
| Back to wall 1700 mm | Long side against the wall | Front and top, rear wall fixed | Moderate, waste and wall junction | Standard recess, full length |
| Freestanding 1700 mm | Needs 100-150 mm clearance around | All sides accessible | Higher, floor-mounted waste and tapware | Open room, feature bath |
| Built-in recess 1700 mm | Sits within the wall recess | Sides sealed in | Higher, tiling around the bath | Replacing a built-in bath like for like |
| Back to wall 1500 mm | Smaller footprint | Front and top, rear wall fixed | Moderate | Narrow rooms, shoulder room |
Those four options aren't variations on a theme. They change the framing, the waste route, the tiling detail and how much of the bath you can reach with a cloth. Make the type decision before anyone frames a wall, because reversing it means undoing waterproofing.
Price is the easy part to compare. Buildmat's back to wall bathtub collection lists a Contura II in 1700 mm at AUD 2,504 for 2026. What that figure doesn't include is the framing, the waterproofing, the plumber or the tiler.
A back to wall bath hides pipes better than any other type and gives you access to them worse than any other type. Settle the access before you fall for the look.

The trade-offs, bath by bath
- Back to wall 1700 mm. The wall side swallows the pipework, the exposed perimeter is short and wipes down fast, and it drops into a standard recess without a freestanding clearance ring. The cost is access. Waste and tapware on the rear wall are effectively sealed in, and the tiled-wall dimension has to be right the first time.
- Freestanding. A feature piece with all four sides reachable and plumbing you can get at. You also take a floor-mounted waste, tapware that has to land somewhere sensible, and a clearance ring around the body. If you're leaning this way, start with freestanding bath options before you commit to a footprint.
- Built-in recess. The most integrated result and the hardest to undo. Replacing one later is a demolition job, and the original bath's dimensions usually aren't documented anywhere you can find them.
- Back to wall 1500 mm. Same installation detail, shorter body, frequently a more upright internal profile, which can feel roomier across the shoulders in a narrow room than a long shallow bath does.
Choose the 1700 mm back to wall when a standard recess already exists and the owner wants full length without a freestanding clearance ring. Choose freestanding when the room is open and all-side cleaning matters. Choose 1500 mm when shoulder room beats lying length.
Which Bathroom Layouts Suit a 1700mm Bath
| Layout | Fit outlook | What to check |
|---|---|---|
| Standard family bathroom with wall-to-wall recess | Usually suits | Finished tile-to-tile width and skirting |
| Narrow bathroom with shower over bath | Tight, may need 1500 mm | Door swing and shoulder room |
| Ensuite with vanity, toilet and shower | Possible if circulation allows | Clear floor path beside the bath |
| Out-of-square Victorian bathroom | Survey first | Wall deviation at each corner |
| Back wall with window or niche | Check before ordering | Sill height and niche depth |
Fit is a room question long before it's a product question. The layout decides whether 1700 mm is realistic.
The step most size guides skip is the one that matters on a renovation site: turning a nominal figure into a measured cavity. The bathtub dimensions buying guide sets out the common lengths clearly enough, but a tiled wall, adhesive, waterproofing build-up and any rear ledge all eat into the space your tape measure saw. An inaccurate wall-to-wall measurement leaves a bath that can't be positioned and can't be removed.
A back to wall bath is also not the same animal as a built-in bath. The rear wall conceals plumbing, but the waste, the overflow, the levelling of the base and the silicone junction still need installation access. On an older Victorian bathroom with irregular walls and corners that aren't square, that access is what decides the job.
How to measure a room properly
- Measure wall to wall at three heights and two points along the run. Skirtings, cornices and out-of-plumb walls mean the top, middle and bottom numbers rarely match.
- Note every corner against a square. A corner 15 mm out over the bath's width is enough to stop a back to wall bath sitting flush at both ends.
- Open the door through its full swing and check the bath end. A door that clears by 30 mm when closed can still foul the rim.
- Confirm where the taps go and how they're operated. A wall mixer over the middle of a 1700 mm bath is a different reach than one at the corner.
If the bath and shower are competing for the same corner, browsing tub and shower layout options before you fix the footprint saves you from a design that only works on paper.
Then compare the numbers the brochure doesn't headline. Internal base length, water depth, rim height and usable shoulder room decide how a bath feels, and a long shallow 1700 mm can be a less generous soak than a shorter, more upright 1500 mm. Rooms where the bath, shower, vanity and toilet all share one footprint are covered in this guide to small bathroom renovation in Melbourne.
The decision rule is unforgiving. The bath fits when the finished cavity exceeds the bath's length plus the allowance the manufacturer specifies, and the circulation around the front stays clear with the door open.
Waste and Trap Placement Behind the Bath
A 1700mm bath can measure perfectly on the plan and still fail in the room if the waste behind it doesn't line up. On a back to wall install, the connection sits behind the bath body, sealed into a space that isn't reachable without pulling tiles or moving the bath. That hidden joint is the fit test, not the length printed on the box.
The NSW Government plumbing guidance on floor waste and fixture requirements, based on AS/NZS 3500.2, sets out two compliant bath connections: an untrapped waste pipe of at least DN 40 discharging to a compliant floor-waste gully, or a trap and waste pipe of at least DN 40.
Which of those options applies depends on the bath model, the site drainage and the plumbing code in your state, so treat it as a decision for the licensed plumber doing the rough-in, not a rule you pick off a diagram. The trap, vent and waste arrangement as a whole has to meet the applicable plumbing code, and the plumber confirms the compliant connection for the chosen bath before anything is sealed in.
Get the arrangement wrong and the symptoms show up later: slow drainage, gurgling when other fixtures run, odour, and a trap seal that pulls out under load.
Access rule: if the waste can't be reached without breaking tiles, the design is wrong, not the fitting.
Pre-rough-in checks, in the order a plumber makes them
- Get the manufacturer's waste-location drawing. It tells you where the outlet sits relative to the finished floor and the bath's rear face, which the plumbing has to match exactly.
- Verify outlet position, finished floor level and fall. A bath set on a raised screed changes the fall you designed for.
- Confirm the floor-waste gully arrangement. Whether there's a compliant gully to discharge into shapes which connection the plumber can use.
- Check that the selected bath allows testing and maintenance access. Some models are far more generous than others around the waste and overflow.
- Pressure-test and inspect before the bath is sealed in. Once the bath is set and tiled, a failed joint is a hole in a wall.
If the plumbing has to move, move it while the frame is open. It's the cheapest hour of the whole project.
Framing, Support and Waterproofing Before Installation
Three stages, in this order, and none of them come apart cheaply once the next one starts.

Framing comes first. The bath needs continuous support along its base and along its rim as the manufacturer specifies, whether that's a timber frame, brackets, or adjustable feet on a bearer. Check it for level before the bath goes anywhere near the wall. A bath that rocks gets shimmed and siliconed, and silicone doesn't fix a flexing base.
Plan the access panel while the framing is open. A panel in the side wall or the adjoining wall, sized so a hand and a tool can reach both the trap and the overflow connection, is the difference between a repair and a demolition.
Waterproofing heights and the lip
The NCC requires walls adjacent to a non-freestanding bath to be water-resistant to at least 150 mm above the bath vessel where the bath is within 75 mm of the wall, and exposed surfaces below the bath lip also need protection, per the NCC 2022 provisions on wet area waterproofing.
Confirm the finished lip height from the manufacturer's data before you set out waterproofing. Skip it and you can leave an under-protected strip behind a bath that looks perfectly correct from the doorway.
Photograph the wall build-up before the tiles go on. Tile thickness, adhesive, waterproofing and any trim all change the number the next person measures.
The installation sequence
- Confirm the model and its finished height. Everything downstream, from waterproofing height to tile coursing, hangs off this one number.
- Frame and level the supports. Set the bath in dry, check level along both axes, then take it out again.
- Cut in the access panel. Mark its position on the frame so the tiler doesn't cover it.
- Waterproof to the required height. Walls to 150 mm above the vessel where the bath sits within 75 mm of the wall, plus everything below the lip.
- Set the bath and seal the junction. Use a compatible sanitary-grade sealant at the bath-to-tile line and keep it flexible.
Rigid contact at the bath lip is what cracks tiles. A movement joint that's been left as a movement joint doesn't.
Accessible Entry and Grab Rail Planning
A 1700 mm bath is long enough that people assume it's also easy to get into. Length doesn't help here at all. What decides it is rim height and step-over effort, and a deep, high-rimmed bath is harder to enter and leave safely than a shorter model with a lower edge. That matters for anyone with hip, knee or balance issues, and for a parent lifting a small child out.
Blocking goes in before the wall closes
Grab rails only work if there's something solid behind them. Decide rail positions while the frame is open and put timber blocking between the studs behind the tiles, near the rim where someone reaches in, and at the far end where they push up from. Retro-fitting a rail into tiled plasterboard is a job you don't want to quote.
Tap position matters as much as the rails. Controls that sit over the middle of the bath force a user to lean across water to reach them. Put the mixer where it can be worked from the floor beside the bath, on the entry side.
- Entry height. A lower entry edge or a shallower internal well reduces the step-over, and it's the single biggest factor in whether the bath stays usable.
- Rails and blocking. Solid fixing at the rim and at the far end, decided before sheeting goes on.
- Slip resistance on the approach. The floor at the bath entry gets wet first, so it needs a textured, slip-rated finish rather than the same polished tile as the vanity wall.
- Space for a seated user. A stool beside the bath needs clear floor and a wall to lean on, and neither appears by accident.
AS 1428.1 is the design reference most specifiers reach for on clearances, rails and circulation, and it's worth reading alongside a project rather than instead of local approval requirements, which still govern what gets signed off.
A bath that's beautiful and impossible to leave safely isn't a feature. It's a liability.
Tile Sizes and Finishes for Bath Surrounds
The tiles around a bath do two jobs. They take the splash, and they set the visual proportions of a 1700 mm run.

| Area | Tile size | Finish | Reason |
|---|---|---|---|
| Long bath wall | 600x1200 | Matt or honed | Fewer grout lines and hides water marks |
| Alcove return | 300x600 | Matt | Cuts neatly around recesses |
| Niche accent | 75x300 or 50x200 | Gloss or textured | Small format suits detail and edges |
| Bath entry floor | 600x600 | Textured matt | Adds grip where people step in |
Setting the joint layout from the centre line
Run the joint layout from the centre line of the bath so the pattern divides the 1700 mm evenly and the cuts land at the ends, not across the middle of the visible face. A 600x1200 on the long wall gives clean horizontal coursing and very few lines to scrub. A 300x600 on the returns cuts neatly around an alcove and the niche edges without slivers.
Finishes drive maintenance more than looks. Gloss wipes clean and shows every water mark, which is why it belongs in a niche or on a splashback panel rather than on the wall behind the bath. Matt and honed surfaces hide marks and sit better with warm tones, and a textured finish earns its place on the floor at the entry where people step in wet.
Grout lines are the maintenance line item nobody budgets for. The wall that takes most of the splash is the last place for small mosaics, because every joint is somewhere water sits and someone scrubs. For a 600x1200 run, Afyon White Matt is listed at $97.20 per box, which works out at $45 per square metre, so a larger format saves labour without a big difference in tile cost.
Here's how those tile and finish decisions land in a finished bathroom.
Our guide to choosing bathroom tiles covers slip ratings and finish matching in more depth if you're specifying the whole surround.
Sealed grout and a flexible sealant at the bath lip are two different things, and the bath lip needs the second one. Grout that cracks at the junction is water finding its way behind the tile.
Confirm Your Measurements Before You Order
The order goes in after the measuring, not before it. A 1700 mm bath only works when the finished wall cavity, the waste route and the tile set-out agree. Check the numbers while the room is still open, then order against those numbers instead of the rough frame.
Run through this list and tick every line.
- Finished recess width. Tile to tile, at three heights, plus whatever allowance the manufacturer specifies beyond the nominal length.
- Finished rim height. Taken off the spec sheet and confirmed on site, not assumed from the last bath you fitted.
- Waterproofing extent. To the required height above the vessel, and below the lip.
- Waste-location drawing. In hand from the manufacturer before the plumber roughs in.
- Access panel position. Marked on the frame, not decided after tiling.
- Floor-waste outlet position. Cross-checked against the plan and the fall.
Price is one line of the quote. Tradelink's 1700 mm baths collection lists a Bao Bon 1700 mm back to wall bath at AUD 1,584 against an RRP of AUD 1,746 in 2026. The step up to a premium model of the same length is small next to waterproofing, plumbing, framing and tiling, which routinely outweigh the difference.
Tile quantity needs 15% wastage added when you order. Cuts at the ends, around a niche and at the bath lip reduce usable pieces quickly, so the box count has to absorb those losses before the job starts.
- Measure the finished recess at three heights and two points.
- Confirm the waste route and the finished lip height with the plumber.
- Order the bath against those numbers, not the room's rough frame.
- Order the tiles with wastage included.
- Book the installer before delivery, so the bath isn't sitting in a hallway for a fortnight.
Call us on 1300 680 580 if you want the surround sizes and finishes checked before you commit, and have the licensed plumber confirm the waste before the bath is set.
Tiles Mate Pty Ltd supplies porcelain, natural stone and mosaic tiles for the bath surround, along with tapware and bathroom fittings. Delivered across Melbourne from its Truganina base, the range suits buyers setting out a 1700 mm bath who need tile sizes, slip-rated floor finishes and joint layouts to line up with the cavity. Visit Tiles Mate Pty Ltd or call 1300 680 580. Bring your finished recess measurements and we'll help you match the format to the space.
Share
-
Tags :
- #1700mm bath
- #back to wall bath 1700mm
- #bath clearances
- #bath waste trap
- #bathroom tile surrounds



